Spn 4364 fmi 1. ... SPN: 4364 | FMI: 31 Aftertreatment 1 SCR Conversion Efficiency - Condition Exists 1 Fault Code 5655 requires that ALL solutions be performed 2 Check for ...

How to fix DEF metering valve on freightliner cascadia, it can help you clear code snp 4364.TOOLS USE:To buy an OTR PERFORMANCE CODE AND FORCE REGEN TOOL PLE...

Spn 4364 fmi 1. 1 11-07-2014, 07:35 AM. We had a customer bring in a 2012 Freightliner with a DD13 in today with a check engine light on. These are the codes that came up: (Active)SPN 4364 FMI 1 SCR NOx Conversion Efficiency Very Low. (Active)SPN 4364 FMI 18 SCR NOx Conversion Efficiency Low. (Active)SPN 3364 FMI 2 Improper DEF Quality.

GHG14 ACM2.1 Fault Codes SPN FMI ACM2.1 FAULT CODE DESCRIPTION GHG14 5488 5 SCR Line Heater #5 Circuit Failed Open 520232 9 NOX Mass Signal Not Available via CAN 520323 3 High Side Digital Output Supply Voltage Circuit Failed High 520323 4 High Side Digital Output UV_DOS Circuit Failed Low 520326 3 Under pressurized DEF system

DD13 with 3364 FMI 2, Spn 4364 FMI 18, 1548 FMI 4. Wondering if I could get the troubleshooting steps for these codes ...2 SPN 4364/FMI 18 - EPA10 Selective Catalyst Reduction NOx Conversion Low Table 1. SPN 4364/FMI 18 Description This Fault Code Sets When The Aftertreatment Control Module (ACM) Detects That The NOx Conversion Is Lower Than A Calibrated Threshold Monitored Parameter Selective Catalyst Reduction (SCR) Inlet NOx Sensor, SCR Outlet NOx Sensor

Feb 26, 2021 · If you dont have an APU or bunk heater and need to leave the truck running for long periods of time, you can try this method to stop from getting spn 4364 Engine light came on today and got this code SPN 4364 FMI 31. Engine is a isx15 cm2350, 2017 t680 with 532,000 miles on it. "Aftertreatment 1 SCR Conversion Efficiency" Along with the code it has started blowing A LOT of extra exhuast during regens. With the extra exhuast during regens what's the likely problem?I got same issue. 4364 fmi 17 .and 520372 520371 fmi16 . I think only way is program acm.They call it magic turn. Only close scr. coz . The road too many pot holes.like AZ i40 . i 20-Shreveport, LA the shock can damage SCR crack by little pieces in the one box.we paid many tax .EEC61 SPN 4364 FMI 18 – Selective Catalyst Reduction Nox Conversion LOW. EEC 61 means Aftertreament Control module (ACM). The ACM module controls the DOC, DPF, DEF, SCR operations. This code sets when the ACM detects that the SCR NOx Conversion efficiency is low. The measurement for this sensor happens by measuring the inlet and outlet NOx ... Mack Truck Models: CHU, CXU, GU, TD. Date: 10/2012. MID 223 Gear Selector Control Unit, Fault Codes. Mack Truck Models: CHU, CXU, GU, TD. Date: 10/2012. Mack Engine - 2007 Emissions Standard Fault Code Manual. Date: 01/2009. The check engine light illuminates in your dash of your Mack Truck.View My Bookmarks 1 0 Title: A26 SPN: 4364 FMI: 18 Supplemental Diagnostics Applies To: All A26 engines CHANGE LOG Please refer to the change log text box below for recent changes to this article: 01/21/2020 - Initial Article Release DESCRIPTION This document will guide the user through supplemental diagnostics for SPN: 4364 FMI: 18 on A26 enginesIf you dont have an APU or bunk heater and need to leave the truck running for long periods of time, you can try this method to stop from getting spn 4364New Shop Info: https://goo.gl/maps/HzwG98iioszjQWRP6TAT Express Inc.972-225-30174140 Langdon Rd.Dallas TX 75241In this video, we go over fault code SPN 4...

SPN 4364/FMI 18. Selective Catalyst Reduction NOx Conversion LowSPN 4364/FMI 18Description This fault code sets when the Aftertreatment Control Module /ECMdetects that the NOx conversion is lower than a calibrated thresholdMonitored Parameter Selective Catalyst Reduction (SCR) Inlet NOx sensor, SCR outletNOx …Spn 3364 fmi 2 Spn 5246 fmi 16 Fmi 5246 fmi 15 Spn 4364 fmi 18 A few weeks ago i changed the output NOX. The check light stayed off for the most part but came back. Would stay on for about a minite then go away. Or i could stop and do a regen on it and code would dissapear. Last weekend i changed out the DEF filter figuring maybe this …To use the table below, first write down the SPN and FMI codes you received from the engine diagnostic gauge. Locate each SPN in the first column and its associated definition to the right in the second column. In the same way, locate the FMI in the forth column and its associated definition to the right in the fifth column. SPN Code. SPN Name : FMI Code. …Sep 13, 2019 · Cummins puts it on the valve cover. Do you have a Cummins engine? Roy. 4364 18. SPN 4364/FMI 18 Description This fault code sets when the Aftertreatment Control Module (ACM) detects that the NOx conversion is lower than a calibrated threshold Monitored Parameter Selective Catalyst Reduction (SCR) Inlet NOx sensor, SCR outlet NOx sensor Typical Enabling Conditions Diesel Exhaust Fluid (DEF ...

112-13 spn 4364-fmi 18 - ghg14. View This TSB. TSB Number: 111-13 NHTSA Number: 10140872 TSB Date: January 11, 2013 Date Added to File: June 11, 2018 Failing Component: Engine And Engine Cooling:Exhaust System Summary: 111-13 spn 4374/fmi 0, 1, 3, 4 - ghg14. View This TSB. TSB Number: 110-13 NHTSA Number: 10140871

Apr 18, 2020 · SPN 4364/FMI 17. DescriptionThis Code Sets When the Aftertreatment Control Module (ACM) Detects Poor Selective Catalyst Reduction (SCR) NOx Conversion Efficiency. Monitored ParameterSCR Inlet NOx Sensor and SCR Outlet NOx Sensor. Typical Enabling ConditionsDiesel Exhaust Fluid (DEF) Dosing Enabled, 1000 to 2100 rpm, 15 to 100% Load.

SPN: 4364 . FMI: 17 . GHG17 . SCR NOX CONVERSION EFFICIENCY ... NOTE: SPN 3361/FMI 5 will set when the DEF dosing unit electrical connector is disconnected. The fault code ... Yes – Go to Step 27 No – For a 1-Box system, replace the DOC/SCR module. For a 2-Box system, replace the SCR module. Complete the ATD checklist to identifySPN 4364/FMI 18. Description. This fault code sets when the Aftertreatment Control Module (ACM) detects that the NOx conversion is lower than a calibrated threshold Monitored Parameter Selective Catalyst Reduction (SCR) Inlet NOx sensor, SCR outlet NOx sensor Typical Enabling Conditions Diesel Exhaust Fluid (DEF) dosing enabled, 1000 - 1500 rpm ...1. Connect DiagnosticLink ®. 2. Check for multiple fault codes. Are any of the following faults active: SPN 4363/FMI 3 or 4, SPN 3246/FMI 3, 4, or 21? a. Yes; Refer to section "SPN 3246/FMI 15 - GHG17" for diagnostics. b. No; Go to step 3. 3. Visually inspect the exhaust system from the turbocharger outlet to the aftertreatment inlet.Apr 1, 2021 · There are 4 cods in my truck ,1, eng 2 001 spn 654, cyl # there are 4 cods in my truck ,1, eng 2 001 spn 654, cyl # injectr 04. 2, eec 061 spn 3720 , dpf ash 15. 3,eec 061 spn 3364, def quality 01. 4, eec 061 spn 3364, def quality 17.( red, yellow, function) … If SPN 1761 FMI 1 fiDEFTL Inducement 3‐5fl is present with no other 1761/X fault codes, the DEF return tube must be removed using the following procedure. Make sure to remove all dirt, debris, snow, etc from around DEF head unit before disassembly to avoid contamination of the DEF in the tank. ...

2015 f750 6.7 Cummins has a son 4364. Fmi 31 an a spn 5246 fmi 18 replace def injector clear codes drive 3 days an it - Answered by a verified Technician. We use cookies to give you the best possible experience on our website.Table 1. SPN 4364/FMI 1. SPN 4364/FMI 1. Description. This fault code sets when the Aftertreatment Control Module (ACM) detects that the NOx conversion is lower than a calibrated threshold. Monitored Parameter. Selective Catalyst Reduction (SCR) Inlet NOx sensor, SCR outlet NOx sensor. Typical Enabling Conditions. How to fix DEF metering valve on freightliner cascadia, it can help you clear code snp 4364.TOOLS USE:To buy an OTR PERFORMANCE CODE AND FORCE REGEN TOOL PLE...0. 2014 International ProStar+. Maxxforce 13, 485,000 miles. VIN: 3HSDJSNR1EN123846. SPN-4364 FMI 18. Fault will clear but returns within 150 miles. Only other codes are non-related. (Body controller, data bank battery, audible alarm) Recently changed EGR cooler and valve and nox out sensor to address those codes.Aug 4, 2022 · FMI codes associated with SPN 4364 include: FMI 18: NOx conversion efficiency low – The SCR system is not effectively reducing NOx emissions, which could be caused by a variety of issues, such as low DEF quality, a malfunctioning DEF injector, or a damaged SCR catalyst. FMI 1: NOx sensor issue – The NOx sensor may be providing incorrect or ... Since the FMI 1 code is tied to the SPN 4364 code, you know it is referring to your NOx system. In this case, this code means: “This fault code sets when the Aftertreatment Control Module (ACM) detects that the NOx conversion is lower than a calibrated threshold” In this case, there are over 20 steps to take to clear the code.2 SPN 4364/FMI 1 – GHG14 This diagnostic is typically SCR NOx Conversion Efficiency Very Low. Table 1. SPN 4364/FMI 1 Description SCR NOx Conversion Efficiency Very Low. Tags: 2014, 10 2214, 4364, Pdf spn 4364 fmi. Information. Domain: Source: Link to …See full list on thecampingadvisor.com SPN 4364/FMI 1. SPN 4364/FMI 1. Description. This fault code sets when the Aftertreatment Control Module (ACM) detects that the NOx conversion is lower than a calibrated threshold. Monitored Parameter. Selective Catalyst Reduction (SCR) Inlet NOx sensor, SCR outlet NOx sensor. Typical Enabling Conditions.2014 Freightliner Cascadia DD15 VIN# ***** Engine has 150ish thousand miles. Codes- SPN 4364 FMI 18 Poor Def quality SPN 3364 FMI 2 Throws Def codes when going up a ...• Internal structure failure of 1-Box™ NOTE: You may also refer to the video on DDCSN Support/Multimedia/EPA10/GHG14 Code SPN: 4364, FMI: 18 Troubleshooting for further …I had a code for a bad inlet nox sensor. So I got it replaced. Both sensors now I’m getting spn 4364 fmi data valid but below normal operating range-moderately. After treatment 1scr conversation efficiency. What else can it be? 2015 prostar Cummins isx 450k miles. Thanks in advance!FMI. Display text. SAE text. 0 “Value too high” Data valid but above normal operational range. 1 “Value too low” Data valid but below operational range. 2 “Faulty data” Data erratic, intermittent or incorrect. 3 “Electrical fault” Voltage above normal or shorted high. 4 “Electrical fault” Voltage below normal or shorted to ...New Shop Info: https://goo.gl/maps/HzwG98iioszjQWRP6TAT Express Inc.972-225-30174140 Langdon Rd.Dallas TX 75241In this video, we go over fault code SPN 4...SPN 1761 is a fault code indicating problem with aftertreatment 1 diesel exhaust fluid tank. See below for the details of each FMI. FMI – Cause: 1 – Level Data Valid But Below Normal Operational Range – Most Severe Level. 3 – Level Voltage Above Normal, Or Shorted To High Source. 4 – Level Voltage Below Normal, Or Shorted To Low Source1 09-19-2019, 06:50 PM (This post was last modified: 09-19-2019, 06:52 PM by reddan.) Help Cascadia code. SPN 4364 FMI 18 SCR NOX Conversion Efficiency Low6,648 satisfied customers. Volvo 2014 Truck have this codes Txid: SPN 3226- After. Volvo 2014 Truck have this codes Txid: SPN 3226- After Treatment outlex NOx FMI 20 (data drifted high) count 1 Tx id 0 SPN 4364 Aftertreatment … read more.Symptoms of SPN 4364 FMI 18 Code. How to Diagnose SPN 4364 FMI 18 Code. Step 1: Check for Fault Codes. Step 2: Inspect the NOx Sensor. Step 3: Check the Wiring Harness. Step 4: Check the SCR System. How to Fix Code SPN 4364 FMI 18. Solution 1: Replace the NOx Sensor. Solution 2: Repair the Wiring Harness.

SPN 3361/FMI 0 SPN 3361/FMI 1 SPN 3364/FMI 1 SPN 3364/FMI 2 SPN 3364/FMI 17 SPN 4364/FMI 1 SPN 4364/FMI 18 Perform a DEF Quantity Test service routine and record the amount of DEF fluid level dispensed. The amount of DEF delivered will vary depending on the diagnostic tool version. If using DDRS/DDDL version 7.05 or …SPN 4364/FMI 18 - EPA10 Selective Catalyst Reduction NOx Conversion Low Table 2. SPN 4364/FMI 18 Description This fault code sets when the Aftertreatment Control Module (ACM) detects that the NOx conversion is lower than a calibrated threshold Monitored Parameter Selective Catalyst Reduction (SCR) Inlet NOx sensor, SCR outlet NOx sensor Typical ...This code sets when the Aftertreatment Control Module (ACM) detects that the Selective Catalyst Reduction (SCR) NOx Conversion efficiency is low. Monitored Parameter. SCR inlet NOx sensor and SCR outlet NOx sensor. Typical Enabling Conditions. Diesel Exhaust Fluid (DEF) Dosing Enabled, 1000 - 2100 rpm, 15 - 100% load.If there are fault codes present other than SPN 3364/FMI 2, SPN 5246/FMI (any) or SPN 4364/FMI 1 or 18, repair them first before continuing this procedure. b. If there are no fault codes, Go to step 2. 2. Using a refractometer from the DEF Test Kit W060589001900, measure the DEF percentage. Is DEF percentage ... SPN 3364/FMI 18 – GHG14 …More Volvo Engine Fault Codes. Data Link (CAN), EMS 2 (Code 6.5, SID 231/SPN 639/2017/PSID 201) can not be started. Engine. Piston Cooling Pressure Sensor (Code 6.8, PPID 8/SPN 520192) Crankcase Ventilation Pressure Sensor (Code 7.8, PID/SPN 153) • Check the control unit installation.SPN 4364/FMI 18 - EPA10. Selective Catalyst Reduction NOx Conversion Low. SPN 4364/FMI 18 Description This fault code sets when the Aftertreatment Control Module (ACM) detects that the NOx conversion is lower than a calibrated threshold Monitored Parameter Selective Catalyst Reduction (SCR) Inlet NOx sensor, SCR outlet …The code is a spn 4364 fmi 31 cummins - Answered by a verified Technician. We use cookies to give you the best possible experience on our website. By continuing to use this site you consent to the use of cookies on your device as described in our cookie policy unless you have disabled them.

I got this code SPN 4364 FMI 31 , I guess Doser module. So, how many more miles can I drive and can I replace it myself. Cummings engine. Ikamob01, Jul 25, 2023.Fault is SPN 4364 FMI 18 - Aftertreatment SCR Catalyst Conversion Efficiency - Data Valid but Below Normal Operating Range - Moderately Severe Level. I have access to Quickserve and Insite. According to the diagnostic tree on Quickserve, first step is to check for other codes active or inactive. There are no other codes in the …SPN 4364/FMI 18. SPN 4364/FMI 18. Description. This code sets when the Aftertreatment Control Module (ACM) detects that the Selective Catalyst Reduction (SCR) NOx Conversion efficiency is low. Monitored Parameter. SCR inlet NOx sensor and SCR outlet NOx sensor. Typical Enabling Conditions. Apr 22, 2017 · 1 04-22-2017, 01:11 AM. So ive been working on this issue with a volvo D13 and i have a code. spn 4094 fmi 1 - NOx limits exceeded due to insufficient reagent quality. went through the diagnostics provided through ptt twice and have not found an issue, however when i clear the code it comes back immediately and i also preformed a forced regen ... SPN 5246 FMI 15 Volvo D13. This is what the Volvo Data sheet has to say about this code: ECM SPN 5246, Aftertreatment SCR Operator Inducement Severity – MID. 128 PSID 46. Data valid but above normal operating range - Least severe level. Moderate SCR system fault detected – Warning fault- Moderate engine derate. 2015 f750 6.7 Cummins has a son 4364. Fmi 31 an a spn 5246 fmi 18 replace def injector clear codes drive 3 days an it - Answered by a verified Technician. We use cookies to give you the best possible experience on our website.1 358.2 SPN 4364/FMI 17 - GHG17 Before starting this troubleshooting procedure, please verify if an Advanced Diagnostic (AD) version is available, ...SPN 4364 FMI 18 DTC Explained, Troubleshooting. Vehicles SPN 3264 FMI [0-16] Troubleshooting Explained ... SPN 3226 FMI [2-20] Explained, Troubleshooting. SPN 4334 is a diagnostic trouble code for Aftertreatment 1 Diesel Exhaust Fluid Doser. FMI 2 – Absolute Pressure Data Erratic, Intermittent Or Incorrect FMI 3 – Absolute Pressure …FMI. Display text. SAE text. 0 “Value too high” Data valid but above normal operational range. 1 “Value too low” Data valid but below operational range. 2 “Faulty data” Data erratic, intermittent or incorrect. 3 “Electrical fault” Voltage above normal or shorted high. 4 “Electrical fault” Voltage below normal or shorted to ...1 09-19-2019, 06:50 PM (This post was last modified: 09-19-2019, 06:52 PM by reddan.) Help Cascadia code. SPN 4364 FMI 18 SCR NOX Conversion Efficiency LowFault Codes (EPA10 & GHG14) 2011-2016. EEC61 SPN 4364 FMI 1 – Selective Catalyst Reduction Nox Conversion Very Low. EEC61 SPN 4364 FMI 18 – Selective Catalyst Reduction Nox Conversion LOW. EEC61 …Verify repairs.SPN 3364/FMI 17 - EPA10Improper Diesel Exhaust Fluid Quality WarningSPN 3364/FMI 17DescriptionImproper Diesel Exhaust Fluid (DEF) QualityMonitored ParameterDEF QualityTypical Enabling ConditionsDEF Refill event detectedMonitor SequenceNoneExecution FrequencyContinuous when enabling conditions metTypical Duration2 hoursDash ...Title: Diagnostics for SPN 3251 FMI 21 DPFDP excessively LOW (Sensor/circuit fault or missing DPF) Applies To: 2013 HD-OBD V-8 Engine CHANGE LOG 07/06/2015 - Added performance recording to Step 4 04/07/2015 - Clarified required calibration level 03/30/2015 - Fixed link to IK12010852 SPN 4364/FMI 1 – GHG14 SCR NOx Conversion Efficiency Very Low Table 1. SPN 4364/FMI 1 Description SCR NOx Conversion Efficiency Very Low Monitored Parameter SCR NOx Conversion Efficiency Typical Enabling Conditions DEF Dosing Valve On, 1000 to 1500 rpm, 15 to 100% load Monitor Sequence None Execution Frequency Continuous when enabling ... Jan 4, 2021 · Verify repairs.SPN 3364/FMI 17 - EPA10Improper Diesel Exhaust Fluid Quality WarningSPN 3364/FMI 17DescriptionImproper Diesel Exhaust Fluid (DEF) QualityMonitored ParameterDEF QualityTypical Enabling ConditionsDEF Refill event detectedMonitor SequenceNoneExecution FrequencyContinuous when enabling conditions metTypical Duration2 hoursDash LampsMIL, CELEngine Reaction25% DerateVerificationParked ... Detroit DD13 EPA10 (2010-13) Fault Code: SPN 4364 FMI 1 (ACM) Selective Catalyst Reduction NOx Conversion Very Low. DESCRIPTION: Selective Catalyst Reduction NOx conversion very low. MONITORED PARAMETER: 1. Selective Catalyst Reduction (SCR) inlet NOx sensor. 2.SPN 3364/FMI 17. DescriptionImproper Diesel Exhaust Fluid (DEF) Quality. Monitored ParameterDEF Quality. Typical Enabling ConditionsDEF Refill event detected. Monitor SequenceNone. Execution FrequencyContinuous when enabling conditions met. Typical Duration2 hours. Dash LampsMIL, CEL. Engine Reaction25% Derate.

SPN 4364/FMI 18 - EPA10 Selective Catalyst Reduction NOx Conversion Low SPN 4364/FMI 18 Description This fault code sets when the Aftertreatment Control Module (ACM) detects that the NOx conversion is lower than a calibrated threshold Monitored Parameter Selective Catalyst Reduction (SCR) Inlet NOx sensor, SCR outlet NOx sensor Typical Enabling Conditions Diesel Exhaust Fluid (DEF) dosing ...

Hello everyone. I'm currently working on a cascadia with a dd13 that have 2 scr effciency codes(SPN 4364 FMI 1 SPN 4364 FMI 18).

Detroit DD13 EPA10 (2010-13) Fault Code: SPN 4364 FMI 1 (ACM) Selective Catalyst Reduction NOx Conversion Very Low. DESCRIPTION: Selective Catalyst …SPN 4364 FMI 1; SPN 4364 FMI 18; SPN 5246 FMI 0; SPN 5246 SPN 15; SPN 5246 SPN 16; No matter which code you have, the troubleshooting steps are all very similar. Troubleshooting The Detroit Diesel DEF Codes Basic DEF Checks First. The first two steps are fairly easy. First, check the DEF supply and airlines. You are looking for …1. Connect DiagnosticLink ®. 2. Check for multiple fault codes. Are any of the following faults active: SPN 4363/FMI 3 or 4, SPN 3246/FMI 3, 4, or 21? a. Yes; Refer to section "SPN 3246/FMI 15 - GHG17" for diagnostics. b. No; Go to step 3. 3. Visually inspect the exhaust system from the turbocharger outlet to the aftertreatment inlet.2 SPN 3364/FMI 1 - GHG14 Improper Diesel Exhaust Fluid Quality Final Warning Table 1. SPN 3364/FMI 1 Description Improper Diesel Exhaust Fluid (DEF) Quality Final Warning Monitored Parameter DEF Quality Typical Enabling Conditions DEF Refill event detected Monitor Sequence None Execution Frequency Continuous when enabling conditions metIf SPN 1761 FMI 1 is present without any other DEFTL fault codes present, follow the repair procedure below. REPAIR PROCEDURE Using a diagnostic service tool, inspect for fault codes related to the DEF (Diesel Exhaust Fluid) tank level (SPN 1761 FMI ‚X™). If multiple 1761 / X Faults are present, they are most likely caused by a low level of DEF in the tank. …NOTE: SPN 520328 FMI 7 or SPN 520327 FMI 4 may also set as a result of this fault. 1. Connect DDDL/DDRS 7.08 SP2 or newer version. 2. Turn the ignition ON (key ON, engine OFF). 3. Check for multiple codes. a. If other faults are active, including SPN 4334/FMI 3, 4, or SPN 4374/FMI 3, 4, troubleshoot the other faults first. b.DD13 with 3364 FMI 2, Spn 4364 FMI 18, 1548 FMI 4. Wondering if I could get the troubleshooting steps for these codes ...

live pga statsculturas de hondurasverizon outage georgia todaykennedy farris Spn 4364 fmi 1 kansas u basketball [email protected] & Mobile Support 1-888-750-3801 Domestic Sales 1-800-221-2929 International Sales 1-800-241-8877 Packages 1-800-800-3762 Representatives 1-800-323-7764 Assistance 1-404-209-3433. More Volvo Engine Fault Codes. Data Link (CAN), EMS 2 (Code 6.5, SID 231/SPN 639/2017/PSID 201) can not be started. Engine. Piston Cooling Pressure Sensor (Code 6.8, PPID 8/SPN 520192) Crankcase Ventilation Pressure Sensor (Code 7.8, PID/SPN 153) • Check the control unit installation.. kansas.jayhawks basketball SPN 4364/FMI 18. Description. This fault code sets when the Aftertreatment Control Module (ACM) detects that the NOx conversion is lower than a calibrated threshold Monitored Parameter Selective Catalyst Reduction (SCR) Inlet NOx sensor, SCR outlet NOx sensor Typical Enabling Conditions Diesel Exhaust Fluid (DEF) dosing enabled, 1000 - 1500 rpm ...SPN 4364 FMI 18 SPN5246 FMI 0 engine derage 25% DEF Quality poor, Check DEF ... Worst case is a failed 1-box! But you need to test for cheaper causes of the fault. Like contaminated DEF, improper concentration of urea in the DEF, biased Nox sensors, excessive DEF build up in in the SCR mixing chamber, over temperature in … ku night at the phogsavanah cavanaugh SPN 4364/FMI 18 - EPA10 Selective Catalyst Reduction NOx Conversion Low SPN 4364/FMI 18 Description This fault code sets when the Aftertreatment Control Module (ACM) detects that the NOx conversion is lower than a calibrated threshold Monitored Parameter Selective Catalyst Reduction (SCR) Inlet NOx sensor, SCR outlet NOx sensor Typical Enabling Conditions Diesel Exhaust Fluid (DEF) dosing ... kentucky vs kansas 2022dockside seafood hickory nc New Customers Can Take an Extra 30% off. There are a wide variety of options. FMI SPN FMI DESCRIPTION QSB QSC QSL9 QSM1 1 QSX1 5 QSK19 QSK23 QS T 30 QSK45 QSK60 QSK78 HHP Level Number (**) 151 (Red) P110 0 110 0 Engine Coolant Temperature High – Critical X 151 (White) P110 0 110 0 Engine Coolant Temperature High – Critical X 1 153 (Yellow) P105 3 105 3 Intake Manifold Temperature Sensor #1It came in with SPN 4094 FMI 31 code showing. I found the flex pipe broken - Answered by a verified Technician. We use cookies to give you the best possible experience on our website. ... 4364 fmi 1, 4364 fmi 18, 3364 fmi 2, 5246 fmi 0, ...- Press the down Arrow to the DM 1 list and press enter. - It shows a SPN 100 FMI 3 engine oil pressure alarm. - Make the repair. - After the alarm clears press the middle button on the left-hand side of the screen. - Press enter to go into general settings and scroll down to eleven sixty and press enter - Press enter again